變壓器電容隔直裝置關(guān)鍵技術(shù)及應(yīng)用分析
李游1,郭超1,卿俊杰1,黃學(xué)海1,趙政2,周波1
(1 國(guó)網(wǎng)成都供電公司,四川 成都 610041;2 西安交通大學(xué) 電氣工程學(xué)院,陜西 西安 710049)
摘 要:為保證變壓器安全穩(wěn)定運(yùn)行,需要利用變壓器直流偏磁抑制裝置控制流過(guò)變壓器中性點(diǎn)的直流。介紹了變壓器電容隔直裝置的基本原理、裝置組成和不同類型隔直裝置的對(duì)比,闡述了正常運(yùn)行狀態(tài)和系統(tǒng)故障時(shí)電容的投切控制邏輯與運(yùn)行模式,結(jié)合實(shí)際采集數(shù)據(jù)分析了電容投切后的電氣量變化,解釋了電容充電回路的振蕩過(guò)程,并對(duì)隔直電容應(yīng)用對(duì)電網(wǎng)保護(hù)的影響進(jìn)行了研究。
關(guān)鍵詞:變壓器;直流偏磁;電容隔直;控制邏輯
中圖分類號(hào):TM403.5 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2019)09-0012-06
Key Technology and Application Analysis of Capacitive DC Blocking Device for Transformer
LI You1, GUO Chao1, QING Jun-jie1, HUANG Xue-hai1, ZHAO Zheng2, ZHOU Bo1
(1 State Grid Chengdu Power Supply Company, Chengdu 610041, China;
2 School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China)
Abstract: In order to ensure the safe and stable operation of the transformer, it is necessary to control the DC flowing through the neutral point of the transformer with the DC bias suppression device. Introduction was made to the basic principle, the device composition and the comparison of different types of capacitive DC blocking devices. This paper described the control logic and operation mode of the capacitive DC blocking device in normal operation state and the system fault. The change of electric quantity after the capacitor switching was analyzed according to the actual acquisition data, and the oscillation process of the capacitor charging circuit was explained. This paper studied on the influence of the blocking capacitor application on the grid production.
Key words: transformer; DC bias, capacitive DC blocking; control logic
參考文獻(xiàn)
[1] 師泯夏,吳邦,靳宇暉,邱愛(ài)慈,李軍浩. 直流偏磁對(duì)變壓器影響研究綜述[J]. 高壓電器,2018,54(7):20-36.
[2] 文習(xí)山, 郭婷婷, 何智強(qiáng), 楊琪, 魯海亮. 直流偏磁相關(guān)問(wèn)題研究綜述[J]. 高壓電器,2016,52(6):1-8.
[3] 彭平,周衛(wèi)華,謝耀恒,劉赟,吳曉文,毛文奇. 關(guān)于地鐵雜散電流引起的變壓器直流偏磁的分析與研究[J]. 變壓器,2017,54(11):26-30.
[4] 劉味果,周衛(wèi)華,葉會(huì)生,彭平,吳曉文. 長(zhǎng)沙地鐵軌道交通對(duì)交流電網(wǎng)的影響及治理措施的研究[J]. 湖南電力,2017,37(1):7-9.
[5] 鄒國(guó)平,姚暉,何文林,孫翔,吳尊東,汪衛(wèi)國(guó). 溪洛渡—浙西±800 kV特高壓直流輸電工程受端電網(wǎng)直流偏磁治理[J]. 高電壓技術(shù),2016,42(2):543-550.
[6] 王莉,劉明予,張予鄂,李立杰. 電網(wǎng)中常用變壓器零序阻抗計(jì)算方法及實(shí)例[J]. 電力系統(tǒng)保護(hù)與控制,2008,36(24);118-120.
[7] 胡志廣, 王峰, 蔡澤祥. 變壓器直流偏磁抑制裝置及其對(duì)繼電保護(hù)影響的分析[J]. 廣東電力,2007(10):20-23.
[8] 彭加成. 地鐵雜散電流對(duì)城市電網(wǎng)變壓器影響及解決方案研究[J]. 神華科技,2018,16(5):55-58.
[9] 王婷,張侃君,文博,陳堃. 大型變壓器中性點(diǎn)串接抑制直流電流電容后對(duì)繼電保護(hù)影響分析[J]. 中國(guó)電力,2017,50(7):164-168.
[10] 楊鑫,馮正偉,汪銘峰,金春山. 電容型隔直裝置對(duì)電網(wǎng)設(shè)備及線路保護(hù)的影響分析[J]. 東北電力技術(shù),2015,36(8):27-31.