低壓大電流短路試驗電壓暫降指標探討
朱英杰
(南京電力設計研究院有限公司,江蘇 南京 210009)
摘 要:大電流低壓短路試驗,其負荷性質主要是沖擊負荷,大的沖擊負荷會導致電網電壓暫降問題。介紹了大電流低壓短路試驗的負荷特征及其基本原理,對電壓暫降EN、IEEE等國際組織以及國內相關標準中給出的電壓暫降指標進行了詳細的總結分析與比較,并給出了低壓短路試驗電壓暫降推薦標準,供相關人員參考。
關鍵詞:短路試驗;電壓暫降;推薦標準;SARFI指標
中圖分類號:TM713 文獻標識碼:A 文章編號:1007-3175(2020)06-0065-04
An Exploration on Voltage Sag Index of Low Voltage and Large Current Short Circuit Test
ZHU Ying-jie
(Nanjing Electric Power Design Institute Co., Ltd, Nanjing 210009, China)
Abstract: In the high-current low-voltage short-circuit test, the load nature is mainly an impact load, and a large impact load will cause a sag in the grid voltage. This paper introduces the basic theory of the low voltage & high current short circuit test and its fundamental principle. Then voltage sag index in national standard and international standards of EN and IEEE and the literatures are summarized, analyzed and compared in detail. Finally, the recommended standard of voltage sag in low voltage short circuit test is given for reference.
Key words: short circuit test; voltage sag; recommended standard; SARFI index
參考文獻
[1] 李煒,李玉春,李向陽. 開關短路試驗對系統電壓影響的仿真研究[J]. 華北電力大學學報,2006,33(5):25-28.
[2] 趙亮,張建軍. 電壓暫降問題及一種有效治理措施[J]. 電氣技術,2011(6):63-66.
[3] 全國電壓電流等級和頻率標準化技術委員會. 電能質量 電壓暫降與短時中斷:GB/T 30137—2013[S].北京:中國標準出版社,2014:3.
[4] 全國電壓電流等級和頻率標準化技術委員會. 電能質量 供電電壓偏差:GB/T 12325—2008[S]. 北京:中國標準出版社,2008:2.
[5] 全國電壓電流等級和頻率標準化技術委員會. 電能質量 電壓波動和閃變:GB 12326—2008[S]. 北京:中國標準出版社,2008:1.
[6] 中國機械工業勘察設計協會. 通用用電設備配電設計規范:GB 50055—2011[S]. 北京:中國計劃出版社,2012:2.
[7] 林焱,吳丹岳,章雪萌,等. 電壓暫降指標的探討[J].電力系統保護與控制,2010,38(3):147-152.