基于直流擾動功率的直流配電網電壓暫降源定位
魯濤1,呂干云1,賈德香2,王程2,徐曉東1
(1 南京工程學院 電力工程學院,江蘇 南京 211167;2 國網能源研究院有限公司,北京 102209)
摘 要:電壓暫降源定位對解決相應供用電雙方糾紛及責任認定等起到重要作用。提出一種基于直流擾動功率法的直流配電網電壓暫降源定位方法,分析了導致直流配電網電壓暫降的典型原因,將故障狀態分解為正常狀態和擾動狀態的疊加,建立直流擾動功率與擾動源位置之間的對應關系,根據直流擾動功率的正負來判斷暫降源的位置。在Simulink平臺上搭建了直流配電網暫降分析仿真模型,分別對直流配電網的外部交流電網故障與內部故障引起的電壓暫降進行源定位分析。仿真實驗結果表明,該方法可有效完成直流配電網電壓暫降源的定位,具有應用范圍較廣、可靠性高的優點。
關鍵詞:直流配電網;電壓暫降源定位;直流擾動功率
中圖分類號:TM711 文獻標識碼:A 文章編號:1007-3175(2020)06-0001-04
Voltage Sag Source Location of DC Distribution Network Based on DC Disturbance Power
LU Tao1, LYU Gan-yun1, JIA De-xiang2, WANG Cheng2, XU Xiao-dong1
(1 School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 2111 67, China;
2 State Grid Energy Research Institute Co., Ltd, Beijing 102209, China)
Abstract: The location of voltage sag source plays an important role in solving the disputes and identifying responsibility between two power supply companies. In this paper, a method for locating source of voltage sag in DC distribution network based on DC disturbance power is provided; the typical causes of the voltage sag in the DC distribution network are analyzed, and the fault state is decomposed into the superposition of the normal state and the disturbance state, and establish the correspondence between the DC disturbance power and the location of the disturbance source, and determine the location of the sag source according to the positive and negative of the DC disturbance power. A DC distribution network sag analysis simulation model was built on Simulink to analyze the source locating caused by the external AC grid fault and internal fault caused by the internal distribution network. Simulation results show that the proposed method can accomplish locates the sag source from upstream or downstream.
Key words: DC distribution network; voltage sag source location; DC disturbing power
參考文獻
[1] 孫鵬飛,賀春光,邵華,等. 直流配電網研究現狀與發展[J]. 電力自動化設備,2016,36(6):64-73.
[2] 史清芳,徐習東,趙宇明. 電力電子設備對直流配電網可靠性影響[J]. 電網技術,2016,40(3):725-732.
[3] BARAN M E, MAHAJAN N R.DC distribution for industrial systems: Opportunities and challenges[J].IEEE Transactions on Industry Applications,2003,39(6):1596-1601.
[4] KAKIGANO H, MIURA Y, ISE T.Low-voltage bipolar-type DC microgrid for super high quality distribution[J].IEEE Transactions on Power Electronics,2010,25(12):3066-3075.
[5] 金一丁,宋強,劉文華. 基于公共直流母線的鏈式可拓展電池儲能系統及控制[J]. 電力系統自動化,2010,34(15):66-70.
[6] PARSONS A C, GRADY W M, POWERS E J, et al. A direction finder for power quality disturbances based upon disturbance power and energy[J].IEEE Transactions on Power Delivery,2000,15(3):1081-1086.
[7] TAYJASANANT T, LI Chun, XU W.A resistance sign-based method for voltage sag source detection[J].IEEE Transactions on Power Delivery,2005,20(4):2544-2551.
[8] HAMZAH N, MOHAMED A, HUSSAIN A.A new approach to locate the voltage sag source using real current component[J].Electric Power Systems Research,2004,72(2):113-123.
[9] 呂干云,孫維蒙,汪曉東,等. 電力系統電壓暫降源定位方法綜述[J]. 電力系統保護與控制,2010,38(23):241-245.
[10] 徐銘銘,肖立業,林良真. 直流配電網單極接地故障定位方法[J]. 電工電能新技術,2015,34(11):55-62.
[11] 徐銘銘,肖立業,王海風,等. 一種基于Prony算法的直流配電網電纜故障定位方法[J]. 電工電能新技術,2015,34(4):1-5.
[12] 和敬涵,張明,羅國敏,等. 一種利用故障暫態過程的柔性直流配電網故障測距方法[J]. 電網技術,2017,41(3):985-992.
[13] 廖建權,周念成,王強鋼,等. 直流配電網電能質量指標定義及關聯性分析[J]. 中國電機工程學報,2018,38(23):6847-6860.