住宅小區(qū)的諧波治理和無(wú)功補(bǔ)償
沈天時(shí)1,劉崇新1,張偉2
(1 西安交通大學(xué) 電氣工程學(xué)院,陜西 西安 710049;
2 西安供電局,陜西 西安 710001)
摘 要: 分析了西安住宅小區(qū)配電網(wǎng)的諧波治理和無(wú)功補(bǔ)償方案的可行性,介紹了諧波治理和無(wú)功補(bǔ)償?shù)幕驹?,并針?duì)小區(qū)電能質(zhì)量現(xiàn)狀,建立網(wǎng)損最小的目標(biāo)函數(shù),兼顧電壓質(zhì)量和設(shè)備費(fèi)用,有效降低了系統(tǒng)的有功網(wǎng)損,且提高了電壓質(zhì)量。該方法對(duì)于現(xiàn)在大規(guī)模配電網(wǎng)的諧波治理具有參考價(jià)值。
關(guān)鍵詞: 住宅小區(qū);有功網(wǎng)損;諧波治理;無(wú)功補(bǔ)償
中圖分類號(hào):TM714.3 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2015)03-0008-05
Harmonic Suppression and Reactive Power Compensation of Residential Quarter
SHEN Tian-shi1, LIU Chong-xin1, ZHANG Wei2
(1 School of Electric Engineering, Xi’an Jiaotong University, Xi’an 71 0049, China;
2 Xi’an Power Supply Bureau, Xi’an 71 0001, China)
Abstract: Analysis was made to the feasibility of the harmonic suppression and reactive power compensation scheme in the distribution network of Xi’an residential quarter. Introduction was made to the basic principle of the harmonic suppression and reactive power compensation. Aiming at the actuality of quality of power supply in residential area, this paper established the target function with the minimum network loss, taking into account the voltage stability and equipment cost at the same time. The scheme effectively reduced active network loss of the system and improved the voltage stability. This method provided certain reference values for the harmonic suppression of large-scaled distribution network.
Key words: residential area; active power loss; harmonic suppression; reactive power compensation
參考文獻(xiàn)
[1] 曹健,林濤,劉林,等.基于最小二乘法和復(fù)連續(xù)小波變換的電力系統(tǒng)間諧波測(cè)量方法[J].電網(wǎng)技術(shù),2009,33(17):86-90.
[2] Ahmed K H, Finney S J, Williams B W.Passive filter design for three-phase inverter interfacing in distributed generation[C]//Compatibility in Power Electronics, 2007.CPE'07. IEEE, 2007:1-9.
[3] Ortúzar M E, Carmi R E, Dixon J W, et al.Voltage-source active power filter based on multilevel converter and ultracapacitor DC link[J].IEEE Transactions on Industrial Electronics, 2006, 53(2):477-485.
[4] 陳愷,王如玫.電力系統(tǒng)諧波治理與有源濾波器[J].華東電力,2008,36(8):55-58.
[5] 吳文輝,劉會(huì)金. 靜止同步補(bǔ)償器(STATCOM) 技術(shù)的研究現(xiàn)狀與發(fā)展[J]. 華東交通大學(xué)學(xué)報(bào),2005,22(2):89-94.
[6] 吳隆輝,卓放,張鵬博,等.一種用于配電系統(tǒng)諧振抑制及諧波治理的新型PAPF控制方法[J].中國(guó)電機(jī)工程學(xué)報(bào),2008,28(27):70-77.
[7] 賈宇虹.并聯(lián)型有源濾波器諧波檢測(cè)與控制技術(shù)研究[D].杭州:浙江大學(xué),2014.
[8] Eltawil M A, Zhao Z.Grid-connected photovoltaic power systems:Technical and potential problems—A review[J].Renewable and SustainableEnergy Reviews, 2010, 14(1):112-129.