CSI-200EA測(cè)控裝置改造的若干問(wèn)題分析
張磊,錢碧甫,劉曦,胡亦涵
國(guó)網(wǎng)溫州供電公司,浙江 溫州 325000
摘 要:以某220 kV變電站的CSI-200EA測(cè)控裝置為例,闡述了該裝置改造過(guò)程的安全措施,從交流回路、信號(hào)開(kāi)入回路、跳合閘回路、閉鎖回路、通信方式等方面分析了改造中出現(xiàn)的問(wèn)題并給出了解決方案。工程結(jié)果表明,此次改造不僅簡(jiǎn)化了回路,增設(shè)了必要設(shè)備,裝置運(yùn)行更加安全可靠,且對(duì)后期的間隔層整體通信和防誤閉鎖都做了預(yù)見(jiàn)性的措施。
關(guān)鍵詞:測(cè)控裝置;改造;安全措施
中圖分類號(hào):TM76 文獻(xiàn)標(biāo)識(shí)碼:B 文章編號(hào):1007-3175(2015)04-0035-03
Some Problems Analysis of Transformation of CSI-200EA Measurement and Control Equipment
ZHANG Lei, QIAN Bi-fu, LIU Xi, HU Yi-han
State Grid Wenzhou Power Supply Company, Wenzhou 325000, China
Abstract: Taking the CSI-200EA measurement and control equipment of a 220 kV substation for example, this paper described the safe measures of the equipment and analyzed the problems discovered in the reforming process of AC circuit, signal circuit, tripping circuit, latch circuit, communication methods and other aspects and gave the corresponding solution. The project result shows that the transformation not only simplifies the circuit by adding to the essential equipments that are more safe and reliable in operation process; also presents predictability measures to improve the latter overall communications of the spacer layer and preventive lockout
Key words: measurement and control equipment; transformation; security measure
參考文獻(xiàn)
[1] 黃國(guó)方,徐石明,周斌,等.新型變電站綜合測(cè)控裝置優(yōu)化設(shè)計(jì)[J].電力系統(tǒng)自動(dòng)化,2009,33(19):77-79.
[2] 黃國(guó)方,徐云燕,奚后瑋,等.新型超高壓變電站測(cè)控裝置的研制[J].電力系統(tǒng)自動(dòng)化,2005,29(6):98-100.
[3] 趙穎博.變電站微機(jī)保護(hù)斷路器控制回路的改進(jìn)[J].電氣應(yīng)用,2009,28(13):56-58.
[4] 趙昕,韓瀟,王春雨.220kV測(cè)控裝置在變電站中的應(yīng)用及檢測(cè)[J].電力系統(tǒng)保護(hù)與控制,2009,37(22):146-148.