變壓器故障診斷專家系統(tǒng)的改良設(shè)計(jì)
鄭燁1,黃海2,趙海峰1,袁帥1
(1 湖南省送變電工程公司,湖南 長(zhǎng)沙 410007;
2 湖南省電力公司長(zhǎng)沙供電分公司,湖南 長(zhǎng)沙 410001)
摘 要: 介紹了變壓器局部放電模型、分類以及局部放電信號(hào)在線檢測(cè)技術(shù),針對(duì)變壓器局部放電的故障診斷,設(shè)計(jì)了一種基于模糊推理的變壓器局部放電專家系統(tǒng),該系統(tǒng)建立在傳統(tǒng)的專家系統(tǒng)和模糊推理器上。通過(guò)仿真實(shí)驗(yàn)結(jié)果表明,改良后的專家系統(tǒng)對(duì)四種典型局部放電信號(hào)的識(shí)別率有較大提高,為進(jìn)行局部放電的模式識(shí)別提供了一種可靠方法。
關(guān)鍵詞: 局部放電;故障診斷;模糊推理;專家系統(tǒng)
中圖分類號(hào):TM41 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2014)01-0047-04
Improved Design of Expert System for Transformer Fault Diagnosis
ZHENG Ye1, HUANG Hai2, ZHAO Hai-feng1, YUAN Shuai1
(1 Hunan Electric Power Transmission & Transformation Corporation, Changsha 410007, China;
2 Changsha Power Supply Branch of Hunan Electric Power Company, Changsha 410001, China)
Abstract: Introduction was made to the model and categories of transformer partial discharge, as well as the online detection technology of partial discharge signals. Aiming at the fault diagnosis of transformer partial discharge, this paper designed a kind of expert system of transformer partial discharge based on fuzzy reasoning. This system was built on the traditional expert systems and fuzzy reasoning unit. The results of simulation experiments show that the improved expert system greatly raised the recognition rate of four typical partial discharge signals, which provides a reliable method for partial discharge pattern recognition.
Key words: partial discharge; fault diagnosis; fuzzy reasoning; expert system
參考文獻(xiàn)
[1] Grunbaum R.SVC Light:A Powerful Means for Dynamic Voltage and Power Quality Control in Industry and Distribution[C]//Eighth International Conference on Power Electronics and Variable Speed Drives, 2000, 475:404-409.
[2] 王國(guó)利,郝艷捧,李彥明,等. 電力變壓器局部放電檢測(cè)技術(shù)的現(xiàn)狀和發(fā)展[J]. 電工電能新技術(shù),2001,20(2):52-57.
[3] 郭俊,吳廣寧,張血琴,等.局部放電檢測(cè)技術(shù)的現(xiàn)狀和發(fā)展[J].電工技術(shù)學(xué)報(bào),2005,20(2):29-35.
[4] 肖燕,郁惟鏞.用于提取局放脈沖的波形匹配識(shí)別方法初探[J].電工技術(shù)學(xué)報(bào),2005,20(5):87-91.
[5] 談克雄,朱德恒,李福棋,等. 發(fā)電機(jī)變壓器放電故障診斷的基礎(chǔ)研究和應(yīng)用[J]. 電力系統(tǒng)自動(dòng)化,2004,28(15):53-59.
[6] Werle P, Borsi H, Gockenbach E. A New Method for Partial Discharge Location on Power Transformers Based on a System Theoretical Approach [ C ] // Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials, 2000,2:831-834.
[7] 黃海,周力行,鄭燁,等.基于HHT實(shí)現(xiàn)變壓器局部放 電模式的識(shí)別[J].電氣工程應(yīng)用,2013(1):27-30.
[8] 廖志偉,孫雅明,葉青華,等.人工智能技術(shù)在電力系統(tǒng)故障診斷中應(yīng)用[J].電力系統(tǒng)及其自動(dòng)化學(xué)報(bào),2003,15(6):71-79.
[9] 胡建中,許飛云,賈民平,等. 故障診斷系統(tǒng)中專家評(píng)價(jià)技術(shù)的研究[J]. 中國(guó)電機(jī)工程學(xué)報(bào),2002,22(12):21-25.
[10] 孫靜,秦世引,宋永華. 模糊Petri 網(wǎng)在電力系統(tǒng)故障診斷中的應(yīng)用[J]. 中國(guó)電機(jī)工程學(xué)報(bào),2004,24(9):74-79.
[11] 黃開(kāi)啟,黃躍飛,劉曉波. 多征兆模糊診斷系統(tǒng)知識(shí)表示及專家系統(tǒng)研究[J]. 中國(guó)機(jī)械工程,2004,15(12):45-47.