串補(bǔ)電容器組保護(hù)間隙和旁路開(kāi)關(guān)的設(shè)計(jì)技術(shù)方案研究
吳盛剛,王衛(wèi)東,陳國(guó)桂,高楊,李彥如
河南省高壓電器研究所,河南 平頂山 467001
摘 要:分析了串聯(lián)補(bǔ)償電容器用保護(hù)間隙和旁路開(kāi)關(guān)的主要用途及其特殊運(yùn)行條件,根據(jù)其主要技術(shù)標(biāo)準(zhǔn)要求,提出多種觸發(fā)間隙和快速開(kāi)關(guān)的技術(shù)方案,對(duì)這些技術(shù)方案進(jìn)行了比較論證,推薦采用真空觸發(fā)間隙和支柱式單斷口結(jié)構(gòu)配電磁斥力操動(dòng)機(jī)構(gòu)的快速開(kāi)關(guān)來(lái)提高電網(wǎng)運(yùn)行可靠性。
關(guān)鍵詞:串聯(lián)電容器;觸發(fā)間隙;快速開(kāi)關(guān);技術(shù)方案
中圖分類(lèi)號(hào):TM531.4;TM564 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2014)12-0001-05
Discussion of Design Technical Solutions on Series Compensation Capacitor Banks with Protective Gap and Bypass Switches
WU Sheng-gang, WANG Wei-dong, CHEN Guo-gui, GAO Yang, LI Yan-ru
Henan High Voltage Apparatus Research Institute, Pingdingshan 467001, China
Abstract: Analysis was made to the main purpose and its special operation conditions of series compensation capacitor with the protective gap and bypass switches. According to its main technical standards requirements, this paper put forward a variety of technical solutions of the trigger gap and high-speed switches. These technical solutions were analyzed and compared. This paper recommended adopting the vacuum trigger gap and pillar type of single fracture structure matched with electromagnetic repulsive force machine high-speed switch to improve the grid operational reliability.
Key words: series capacitor; trigger gap; high-speed switch; technical solution